easyeda-mcp-pro
Installed, started with no arguments, no environment and no input, and listed its tools. Run 2026-11-16.
Needs to start: nothing
Returns a result when called with no setup: 5 of 5 tools tried
Contacts while installing and starting: nothing
Its tool definitions changed since version 1.14.0. If you approved the earlier ones, read them again.
What it contacted
Nothing besides the npm registry it was installed from. Watched from outside its sandbox while it was installed and started with no input. Its tools may still contact things when called.
Starting it
npx -y easyeda-mcp-pro@1.15.6
Installing a package runs its code. Use a sandbox for anything you have not read.
Calling its tools
5 tools that take no input and look read-only were called once with nothing. 5 returned a result.
easyeda_health_check | Returned a result under 0.1 s · 310 characters |
easyeda_bridge_status | Returned a result under 0.1 s · 250 characters |
easyeda_get_capabilities | Returned a result under 0.1 s · 3,420 characters |
easyeda_get_server_config | Returned a result under 0.1 s · 2,133 characters |
easyeda_get_tool_profiles | Returned a result under 0.1 s · 1,492 characters |
During the calls it contacted nothing it had not already contacted.
Only tools whose names read like looking something up, with no required input, are tried, five at most. Tools that need input, and anything that sounds like it changes or sends something, are not called.
What its tools tell an agent
In the tool descriptions, nothing that talks about the user, other tools or private files, or uses hidden characters.
Found by simple pattern rules in each tool's description (up to 3,000 characters), quoted as written. Parameter descriptions are not scanned. A clean result is not a safety review.
Tools
easyeda_health_check
Return server health status in one call: runtime version, active profile, bridge state, EasyEDA version, keyless sourcing state, and starter catalog size. Intended as the single actionable status check after first connecting the bridge extension.
easyeda_bridge_status
Check EasyEDA Pro bridge connection status, version, and capabilities.
easyeda_get_capabilities
Return server capabilities, including available profiles, enabled feature flags, and supported operations.
easyeda_get_server_config include_flags
Return safe (redacted) server configuration. Secrets are never exposed.
easyeda_get_tool_profiles
List available tool profiles and their descriptions.
77 more tools
easyeda_get_feature_flags
Return current feature flag values.
easyeda_observability_report includeRecentEvents
Return latency budgets, runtime metrics, cache/vendor timing snapshot, and storage retention policy for performance diagnostics.
easyeda_run_self_test
Run internal self-test to verify server integrity, config, and bridge connectivity.
easyeda_api_inventory filter
Inspect the live EasyEDA extension runtime and list available documented API classes, runtime paths, and methods.
easyeda_schematic_nets projectId, pageUuid, scope
List nets from the current schematic context. Explicit focused scope is supported; page/all_pages scopes fail closed on EasyEDA Pro 3.2.149.
easyeda_schematic_components projectId, limit, offset, pageUuid, scope
List schematic components with IDs, references, values, footprints, placement, and project-instance device IDs. Omitted scope preserves legacy all-pages; focused/all_pages are supported, pageUuid is not. Project-instance device IDs are not valid place_component deviceItem values; use schematic_search_device.
easyeda_schematic_wires projectId, limit, offset, pageUuid, scope
List wire segments with primitiveId, coordinates, net, color, and style; paginate past 50 with offset. Explicit focused is supported; page/all_pages fail closed on EasyEDA Pro 3.2.149. primitiveId is required by delete_primitive/modify_primitive.
easyeda_schematic_net_detail projectId, netName, pageUuid, scope
Get full details for a specific net in the current schematic context including connected pins and components. Explicit focused scope is supported; page/all_pages scopes fail closed on EasyEDA Pro 3.2.149.
easyeda_schematic_search_device key, libraryUuid, classification, symbolType, itemsOfPage, page, minimal
Search for schematic symbols/devices in the EasyEDA library by keywords. Full results carry the library's complete metadata object per device; pass minimal:true to get back only uuid/libraryUuid/name/pin_count/symbol_type when that is all you need.
easyeda_schematic_device_subparts deviceUuid, libraryUuid
Read the exact sub-part names and declared footprint from a device library record. Use the UUIDs returned by search_device. This is read-only metadata: it does not place units, prove shared designators, pin connectivity, or a single BOM component.
easyeda_schematic_sheet_info projectId, pageUuid, scope
Return read-only schematic sheet metadata. Supports focused, pageUuid/page, and all_pages page-list reads without changing EasyEDA focus; aggregate geometry is never invented.
easyeda_schematic_plan_safe_region projectId, contentWidth, contentHeight, preferredRegion, margin, titleBlockKeepout
Compute a safe schematic drawing region before placing components. Uses live sheet info when available, assumes EasyEDA bottom-left coordinates, reserves the default lower-right title-block keep-out, and returns an anchor/bounds plan that avoids title-block overlap.
easyeda_schematic_verify_write projectId, netName, beforeComponentCount, expectedComponentCountDelta, includeWireCheck
Read back schematic state after an agent-authored write. Returns component-count delta evidence and optional netlist validation so agents can confirm a placement or connection before continuing.
easyeda_schematic_component_pins primitiveId
Get exact pin primitive IDs, numbers, names, coordinates, native no-connect state, and pinType for a schematic component by its primitive ID. pinType is EasyEDA's own symbol-library field and is unreliably authored (often "Undefined" even on real ICs) — treat it as a weak hint, not ground truth.
easyeda_schematic_check_collisions projectId
Scan every component's real pin coordinates and report any (x,y) shared by two or more components — a silent-short risk the native NET_COLLISION guard misses for never-wired pins. Run after manual placement outside easyeda_workflow_* tools (which reconcile this automatically).
easyeda_schematic_validate_netlist projectId, includeWireCheck, pageUuid, scope
Validate inferred nets/floating pins and cross-check native ERC. Only native noConnected=true excludes a pin; unavailable/malformed state stays visible. `valid` requires clean inference and zero native errors. Explicit focused is supported; page/all_pages fail closed on EasyEDA Pro 3.2.149.
easyeda_schematic_audit_imported_design projectId, includeInfo, componentLimit
Read the live schematic without modifying it, build a canonical model, and report imported net aliases, duplicate or missing references, unresolved metadata expressions, missing values/footprints, and ambiguous BOM classification. Includes a preview only; it never renames nets or changes components.
easyeda_schematic_preview_imported_normalization projectId, componentLimit, normalizeNetNames, annotateReferences, resolveMetadataExpressions, componentOverrides
Read the live schematic and produce a deterministic, read-only normalization plan with a stable plan ID, model hash, proposed net-name/reference/metadata operations, validation gates, warnings, and blockers. This tool never writes to EasyEDA.
easyeda_schematic_place_component deviceItem, x, y, subPartName, designator, uniqueId, rotation, mirror, addIntoBom, addIntoPcb, dryRun, verifyAfterWrite, checkPlacementCollision, collisionRadius, projectId, transactionId, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Place device from schematic_search_device (project-local IDs invalid). For multi-unit parts provide exact subPartName + shared designator and uniqueId; native readback checks linkage. On timeout inspect before retry. projectId + transactionId enables rollback; without transactionId the write is standalone.
easyeda_schematic_add_wire points, netName, color, lineWidth, lineType, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Add a wire connecting schematic coordinates/pins — real native connectivity. Same `netName` connects pins globally: separate stubs sharing one name merge into one net (no label needed). NET_COLLISION guards touched points against a foreign net's wire, pin, or flag/port — not mid-segment crossings.
easyeda_schematic_add_text x, y, content, rotation, color, fontName, fontSize, bold, italic, underline, alignMode, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Place free-standing text on the schematic sheet (section headers, notes, block labels) — cosmetic/organizational, not a net label. color must be a hex string and fontName a real font (e.g. "Arial") — untyped placeholders create nothing despite returning ok.
easyeda_schematic_add_rectangle x, y, width, height, cornerRadius, rotation, color, fillColor, lineWidth, lineType, fillStyle, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Draw a rectangle on the schematic sheet — section dividers/grouping boxes for organizing a busy schematic into labeled functional blocks (pair with add_text for the title). Cosmetic only. x/y is the top-left corner; fillColor "none" leaves it unfilled.
easyeda_schematic_add_circle centerX, centerY, radius, color, fillColor, lineWidth, lineType, fillStyle, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Draw a circle on the schematic sheet — decorative marker or custom symbol element. Cosmetic only, no electrical meaning. fillColor "none" leaves it unfilled.
easyeda_schematic_add_polygon points, color, fillColor, lineWidth, lineType, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Draw a closed polygon on the schematic sheet from 3+ vertices — custom decorative shapes, callout arrows, or block diagram elements. Cosmetic only, no electrical meaning.
easyeda_schematic_delete_primitive primitiveIds, projectId, transactionId, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Delete supported schematic primitives by UUID. BETA text delete is blocked: native success can be lost after restart. Native success does not prove persistence. Use projectId + transactionId for supported rollback-backed deletion. Without transactionId, deletion is standalone.
easyeda_schematic_modify_primitive primitiveId, property, projectId, transactionId, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Modify a schematic primitive while preserving omitted fields. With transactionId and projectId, snapshot and restore after failed writes/read-back. Connected or unverified component moves fail closed before mutation.
easyeda_schematic_set_pin_no_connect projectId, primitiveId, pinNumber, noConnected, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Set or clear EasyEDA Pro's native No Connect marker on one exact component pin. This changes the component pin noConnected state; it does not create a net, label, power flag, or short-circuit flag. The bridge rejects missing/ambiguous pins and verifies the native readback after the write.
easyeda_schematic_create_net_flag projectId, netName, x, y, rotation, identification, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Create a named net flag/label. With `identification` (Power/Ground/AnalogGround/ProtectGround) it places a power-flag symbol binding to a coincident pin (use for VCC/GND). Without it, a generic net label — cosmetic only; connect pins with add_wire stubs sharing one netName.
easyeda_schematic_create_net_port projectId, netName, x, y, portType, rotation, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Place a hierarchical net port (off-sheet connector) on the schematic. Net ports create named connections that span multiple schematic sheets, appearing as real SCH_Net entries in the netlist.
easyeda_schematic_connect_pin_to_net projectId, primitiveId, pinNumber, netName, stubLength, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Create real EasyEDA connectivity for a pin: draws a short wire stub from its exact coordinate, tagged with netName. Same-netName wires merge globally, so this joins the pin to everything else on that net — visible to ERC, ratsnest, and autorouting.
easyeda_schematic_connect_pins_by_net projectId, netName, pins, stubLength, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Bulk variant of connect_pin_to_net: draws a real wire stub from each pin, tagged with netName, so all listed pins (and anything else already on that net) merge into one net. Visible to ERC, ratsnest, and autorouting. A pin that fails (e.g. collision) is reported in failures rather than aborting the batch.
easyeda_project_save projectId, confirmWrite
Save only the exact focused EasyEDA project/document. Native acknowledgment is NOT durable persistence: success=false until verified after cold reopen. On Pro 3.2.209, use GUI Ctrl+S then reopen the document to verify. Never blindly retry unverified writes.
easyeda_schematic_set_title_block fields, showTitleBlock, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Update schematic title block text fields (Company, Version, Drawn, Reviewed, Page Size). Only these 5 are exposed — writing Symbol/Border/Device/etc once corrupted a real title block; those are read-only natively and must be fixed via the EasyEDA Pro UI.
easyeda_schematic_sync_to_pcb projectId, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Request a schematic-to-PCB sync (SCH_Document.importChanges). CAUTION (live-verified): opens a confirmation dialog in EasyEDA Pro's UI a HUMAN must approve — success here only means the request was sent, not that components appeared. Ask the user to approve the dialog, then verify with pcb_components.
easyeda_schematic_batch_write projectId, transactionId, operations, atomic, dryRun, confirmWrite, expectedPcbUuid, expectedSchematicPageUuid
Apply up to 200 validated schematic create, modify, pin no-connect, and delete operations in one snapshot-backed transaction. Any failure rolls the whole transaction back. Delete is limited to safely recreatable drawing primitives.
easyeda_project_begin_transaction projectId, label, maxOperations, ttlSeconds
Open an in-memory, document-scoped transaction for snapshot-backed schematic writes. Only tools passed transactionId participate; standalone schematic writes are not auto-captured. Only one active transaction is allowed per document. Beginning a transaction does not modify EasyEDA.
easyeda_project_get_transaction_status transactionId
Read transaction state, validation results, operation hashes, and rollback status without exposing captured primitive snapshots.
easyeda_project_validate_transaction transactionId, expectedOperationCount, requireAppliedOperations, requireBridgeConnected
Run transaction consistency gates before commit: bridge availability, pending/failed operation checks, optional expected operation count, and optional requirement for at least one applied write.
easyeda_project_commit_transaction transactionId, confirmWrite
Finalize a transaction after its writes and validation gates succeed. Commit removes rollback eligibility and releases the document transaction lock.
easyeda_project_rollback_transaction transactionId, confirmWrite
Controlled write: restore applied schematic primitive snapshots in reverse order, verify each restored hash, and report partial rollback explicitly instead of hiding inconsistencies.
easyeda_bom_generate projectId, format, groupBy
Generate a bill of materials for the project with grouping and formatting options.
easyeda_bom_validate projectId
Validate the project BOM against LCSC inventory to identify missing, obsolete, or alternate parts.
easyeda_bom_export projectId, format, filePath
Export the bill of materials to a file on disk in the specified format.
easyeda_bom_sourcing projectId, suppliers
Retrieve pricing and availability information for all parts in the project BOM from specified suppliers.
easyeda_bom_quality_report projectId, low_stock_threshold, require_mpn, require_footprint, stale_vendor_data_seconds, minimum_quality_score
Generate a BOM quality report that identifies unavailable, single-source, missing-MPN, missing-footprint, and low-stock items across configured suppliers.
easyeda_drc_run projectId, rules
Run EasyEDA Pro's native PCB DRC and refresh its visible DRC panel. Requires a PCB document to be focused; otherwise returns an indeterminate not_available result with an actionable focus error. Returns coarse severity counts; per-violation detail stays in EasyEDA Pro.
easyeda_erc_run projectId, checks, pageUuid, scope
Run native schematic ERC and supplement aggregate counts with inferred_floating_pins. Requires a focused schematic. Explicit focused is supported; page/all_pages fail closed on EasyEDA Pro 3.2.149. Native counts remain authoritative; unavailable focus returns not_available.
easyeda_semantic_erc_validate projectId, nets, devices, interfaces, datasheetConstraints
Run typed semantic ERC over caller-supplied pin/net metadata. Optional exact part/package/revision constraints report source-declared voltage, I/O supply-domain, intentional NC, support-part and headroom evidence; a requested but unverified datasheet review never yields passed=true or electrical approval.
easyeda_semantic_erc_auto projectId, datasheetConstraints
Read LIVE nets, devices and pins for semantic ERC. Optional caller-declared datasheet rules compare pin/net identity without source authentication; UNKNOWN evidence never yields passed=true or electrical approval. Pin types remain inferred; incomplete inventories block datasheet review.
easyeda_power_tree_analyze projectId, rails, sources, regulators, loads, protections, capacitors, limits
Analyze supply sources, regulators, loads, protection, bulk capacitance, current budget, dropout, and regulator thermal risk. Returns machine-readable issues and a human-readable summary.
easyeda_post_write_qa projectId, policy, useNativeChecks, manualDrcMessages, manualErcMessages, drc, erc
Run and classify post-write schematic QA after generated edits. Combines native DRC/ERC results with policy-aware classification so duplicate net names, free networks, and unconnected pins are reported as pass/fail/inconclusive instead of raw warning counts.
easyeda_rule_check_summary projectId
Get a summary of all design and electrical rule check results for the project.
easyeda_board_layers projectId
List all layers in the PCB design including signal, power, plane, and mechanical layers.
easyeda_board_stackup projectId
Get the PCB layer stackup including thickness, material, and dielectric constants.
easyeda_board_design_rules projectId
Read the active EasyEDA DRC profile and its global safe-spacing matrix. Net-class membership and per-net overrides are reported separately and are not inferred.
easyeda_board_dimensions projectId
Get PCB outline dimensions, drilled-pad counts and minimum drill from verified pad/via inventories. Missing native drill evidence remains unknown; mounting-hole classification requires explicit evidence.
easyeda_board_features projectId
Get counts of board features. zones counts copper Pour boundaries only; native Fill and Region primitives are reported separately as fills and regions.
easyeda_pcb_components projectId, limit, offset
List native PCB components, designators, footprints and positions. Requires exact active project UUID and a focused PCB document; mismatched or missing focus returns not_available, not a successful empty list.
easyeda_pcb_pours projectId, limit, offset
Read native PCB copper Pour boundaries and associated Poured fills: IDs, net, layer and fill count. Missing, unsupported and mismatched beta API results stay distinct from verified associations. Requires exact focused project and PCB. Read-only; no rebuild, create, or edit.
easyeda_pcb_fills projectId, limit, offset
List native PCB Fill primitives separately from copper pours/zones, including net/layer, fill mode, line width, lock state, and a bounded normalized polygon representation. Netless fills are returned explicitly with netless=true. Read-only; no Fill mutation is exposed.
easyeda_pcb_regions projectId, limit, offset
List native PCB Region primitives separately from copper pours/zones, including layer, region rule types/name, line width, lock state, and a bounded normalized polygon representation. Read-only; no Region mutation is exposed.
easyeda_pcb_tracks projectId, limit, offset
List native copper track segments and net/layer geometry. Requires exact active project UUID and focused PCB; mismatched or missing focus returns not_available, not a successful empty list.
easyeda_pcb_vias projectId, limit, offset
List native PCB vias, nets and dimensions. Requires exact active project UUID and focused PCB; mismatched or missing focus returns not_available, not a successful empty list. Units follow native PCB coordinate scale.
easyeda_project_list
Read team-scoped EasyEDA projects and active identity. Only the active project can be verified open; unknown projects report open=null. No native project or document changes.
easyeda_project_open projectId, confirmWrite
Open an EasyEDA project by UUID only when no other document is open. Requires explicit write confirmation and read-back of active project. Never silently switches away from an open document.
easyeda_project_close projectId, mode, confirmWrite
Default refuses when dirty status is unknown. Explicit confirmed save-and-close requires a trusted native save; schematic pages with unverified durable persistence fail closed instead of risking data loss. Explicit discard is destructive.
easyeda_pcb_constraint_check projectId, boardData
Run PCB constraint validation against the board design. Checks board outline, layer stackup, net classes, clearance rules, keepout areas, placement zones, mounting holes, fiducials, and manufacturing constraints.
easyeda_pcb_production_review projectId, boardData, gateMode, manufacturerProfile
Review PCB DFM/DFA/DFT findings with optional caller-declared manufacturer process limits. Missing native measurements remain UNKNOWN; no fabrication approval or ordering action.
easyeda_pcb_constraint_report projectId, boardData
Generate a human-readable report explaining which PCB constraints were applied and which require manual review.
easyeda_engineering_review projectId
Read PCB inspection evidence and summarize existing constraint rules with stable findings, source provenance and explicit unknowns. Does not execute ERC, DRC, design writes or exports, and cannot approve fabrication.
easyeda_pcb_route_geometry_review projectId, intent, minWidthMm, minClearanceMm, differentialPair, placementRelations, includeNativePadContacts, traceCurrent
Read native PCB tracks/vias in 200-row pages, bounded at 1200 tracks and 600 vias, plus opt-in source-declared component-origin/pad-pair and exact native endpoint-chain observations. Incomplete/non-atomic evidence remains UNKNOWN; no DRC or fabrication approval.
easyeda_export_gerbers projectId, filePath, drillFormat, excludeLayer, ledPanel, productionReview
Export PCB design to Gerber files for PCB fabrication.
easyeda_canvas_capture tabId
Capture the visible EasyEDA schematic/PCB canvas as PNG. Captures the given tab or last-focused tab. Oversized PNGs are downsampled without cropping and report original/final dimensions.
easyeda_canvas_capture_region left, right, top, bottom, tabId
Zoom to a rectangular document/canvas region and capture it as PNG. This moves the visible viewport. Oversized PNGs are downsampled without cropping, preserving the complete requested region.
easyeda_canvas_locate x, y, scaleRatio, tabId
Zoom canvas to x/y (PCB/footprint: mil; schematic/symbol: 0.01 inch). scaleRatio 200 means 200%. Returned viewport bounds use requested document units only when center-based 1x/10x scaling is verified; otherwise the unit is unverified. Changes the user's viewport.
easyeda_library_update_device_metadata libraryUuid, deviceUuid, properties, expectedFingerprint, thumbnailPolicy, expectedThumbnailSha256, mode, confirmWrite, writeMode
Preview/apply string-valued Personal Device properties with explicit thumbnail reinsertion. Requires preview fingerprint, image hash and confirmWrite. Verifies saved metadata, identical image bytes and preserved fields. Limited to EasyEDA 3.2.206; never infers engineering approval.
easyeda_design_rules_lookup topic, currentA, traceWidthMils, traceWidthMm, neckDownWidthMm, manufacturerMinWidthMm, environment, temperatureRiseC, layer, copperWeightOz, voltageV, location, protocol, category, loadA, minBulkCapacitanceUfPerA, minBulkCapacitanceUf, id, review
Look up bounded trace/current, clearance, routing, decoupling, bulk capacitance and DFM guidance. Source-declared isolation, creepage and ESD/EMC review reports warnings or UNKNOWN, never safety certification.
Descriptions are the package's own words, cut at 3,000 characters. Treat them as data.
Files it wrote
/tmp/ .easyeda-mcp-pro/ easyeda-mcp-pro.sqlite /tmp/ .easyeda-mcp-pro/ bridge-listener.lock/ owner.json /tmp/ .easyeda-mcp-pro/ easyeda-mcp-pro.sqlite-wal /tmp/ .easyeda-mcp-pro/ easyeda-mcp-pro.sqlite-shm
Paths inside its sandbox, where its home folder is /tmp and its own folder cannot be written to.
Install facts
| License | AGPL-3.0-only |
|---|---|
| Needs | node >=24 <25 |
| Source | github.com/oaslananka/easyeda-mcp-pro |
| Install scripts | None declared by it or anything installed with it. |
| Tarball | sha512-ShaTTADL5OI8rdVpUOnS9O0A5KRLoElLKkGJTnUTTrHuF8Hda5OU4c+wWOFxXmxUXZdoIEAo2I6kASi/8Dzocg== |
Versions reported
| Version | Run | Result | Tools |
|---|---|---|---|
| 1.15.6 | 2026-11-16 | Starts with no setup | 82 |
| 1.14.0 | 2026-11-12 | Starts with no setup | 79 |
Check this report yourself
This site did not write the report. A public job on a GitHub-hosted machine did: the run, from this commit of the open-source runner. GitHub signed a token that names that job and the hash of the report, so any edit since would show.
Report as JSONExact text and tokenHow to verify it
Show it on your README
[](https://bragproof.smaverk.com/r/easyeda-mcp-pro)
New version out? Ask for a fresh report.